asna.com Sign In
Error 683: QUSCRTUQ create user queue OS/400 api failure. 

SUMMARY

Error 683: QUSCRTUQ create user queue OS/400 api failure.

SYMPTOMS

After installing Datagate400 you are unable to connect because you're get the error "QUSCRTUQ create user queue OS/400 api failure".  Other users with more authority may be able to connect successfully while other users cannot.

CAUSE

The cause for this error is that there is not enough permissions for either the DG8SVCPRF user profile, the user profile, or a group profile (if used)  to create the *USRQ objects in the installation library.  

RESOLUTION

Possible solutions:

  1. Install Datagate400 using QSECOFR profile.
  2. Verify that the profile DG8SVCPRF has *ALL permissions to the installation library and the ASNA_DG8 library. 
  3. Verify that installed library has *Public *Change authority.
  4. If group profiles are used, make sure that the profile also has *CHANGE permissions to the installation library.


Related Articles
Article Downloads
 
Keywords:
Datagate, API, Failure, Connect, permission,
Article ID: 481 
Category: ASNA DataGate; ASNA DataGate : Installation and Registration; ASNA DataGate : ASNA DataGate for System i; ASNA DataGate : ASNA DataGate for Windows Servers and Desktops 
Applies To: Datagate 400 
Article Date: 1/8/2009